top of page
Our Recent Energy Models
You’re invited to browse a selection of recently completed projects below.
ESDS v4.0 compliance incentive study modeling
Village at 47th Tukwila, WA
2018 WSEC compliance
17724 15th Avenue NE, Shoreline, WA 98155
LEED v4 compliance
18553 8th Ave NE, Shoreline, WA 98155
LEED v4.0 compliance model
2100 Queen Anne Ave N, Seattle, WA 98109
SEC 2015 code compliance
4508 CALIFORNIA AVE, SEATTLE, WA 98116
hed.
hed.
12548 Lake City Way NE, Seattle, WA 98125
The proposed Polaris At Lake City is a mixed use development at 12548 Lake City Way NE, Seattle, WA 98125. It is a 258,125 SF six-story mixed use apartment building with 260 dwelling units at levels P2-L6, parking garage at level P1 and with commercial spaces at L1 level.
The proposed design complies with Evergreen Sustainable Development Standard (ESDS) Version 3.0.1 by achieving 13.3% (required min 12.58%) energy savings over the standard reference design with C406.3 Reduced Lighting Power and C406.5 On-site Renewable Energy additional efficiency package options.
The proposed design complies with Evergreen Sustainable Development Standard (ESDS) Version 3.0.1 by achieving 13.3% (required min 12.58%) energy savings over the standard reference design with C406.3 Reduced Lighting Power and C406.5 On-site Renewable Energy additional efficiency package options.
916 N 143RD ST, SEATTLE, WA 98133
The Linden Apartments is a new seven‐story, multi‐family residential building with surface parking and ground floor residential common areas. The project is located at 916 N 143RD ST, SEATTLE, WA 98133. The proposed design has a total of 200 residential units. The gross square footage of the building is 183,647 ft2.
The proposed design complies with 2015 Seattle Energy Code (SEC2015) and Evergreen Sustainable Development Standard (ESDS) Version 3.0.1 by achieving 15.54% (required min 15.37%) energy saving over the standard reference design with C406.3 Reduced Lighting Power and C406.9 Reduced air leakage additional efficiency package options. Additional energy saving measures to achieve ESDS 10 points are better envelope, ERV systems in commercial area and corridors, VRF system in commercial area, Heat Pump Water Heater and more efficient lighting and ventilation equipment.
The proposed design complies with 2015 Seattle Energy Code (SEC2015) and Evergreen Sustainable Development Standard (ESDS) Version 3.0.1 by achieving 15.54% (required min 15.37%) energy saving over the standard reference design with C406.3 Reduced Lighting Power and C406.9 Reduced air leakage additional efficiency package options. Additional energy saving measures to achieve ESDS 10 points are better envelope, ERV systems in commercial area and corridors, VRF system in commercial area, Heat Pump Water Heater and more efficient lighting and ventilation equipment.
7930 RAINIER AVENUE S, SEATTLE, WA 98118
The Rose Street II consists of two new 4‐5 story buildings containing 182 residential units with parking and ground floor residential common areas. The project located at 7930 Rainier Ave S, Seattle, WA 98118. The gross square footage of two building is 204,196 ft2.
The proposed design complies with 2015 Washington State Energy Code (WSEC2015) and Evergreen Sustainable Development Standard (ESDS) Version 3.0.1 by achieving 18.51% (required min 15.37%) energy saving over the standard reference design with C406.3 Reduced Lighting Power and C406.9 Reduced air infiltration additional efficiency package options. Additional energy saving measures to achieve ESDS 10 points are better envelope, ERV systems in commercial area and corridors, VRF system in commercial area, Heat Pump Water Heaters and more efficient lighting and ventilation equipment.
The proposed design complies with 2015 Washington State Energy Code (WSEC2015) and Evergreen Sustainable Development Standard (ESDS) Version 3.0.1 by achieving 18.51% (required min 15.37%) energy saving over the standard reference design with C406.3 Reduced Lighting Power and C406.9 Reduced air infiltration additional efficiency package options. Additional energy saving measures to achieve ESDS 10 points are better envelope, ERV systems in commercial area and corridors, VRF system in commercial area, Heat Pump Water Heaters and more efficient lighting and ventilation equipment.
11.png
Reduce your construction costs & carbon emissions with energy modeling report
bottom of page